Scientific Reports volume 12, Article number: 11916 (2022) Cite this article 675 Accesses 1 Citations Metrics details In single-port thoracoscopic lobectomy, surgical instruments are likely to collide

Scientific Reports volume 12, Article number: 11916 (2022) Cite this article

675 Accesses

1 Citations

Metrics details

In single-port thoracoscopic lobectomy, surgical instruments are likely to collide and interfere with each other. We used magnetic anchor technique to design an anchoring device suitable for thoracoscopic surgery, and verified the safety and feasibility of its use in animal experiments. Ten Beagles were used as models, and magnetic anchor technology was used to assist thoracoscopic lobectomy. During the operation, a self-designed magnetic anchored internal grasper was used in place of the traditional laparoscopic grasping forceps. The operation time, intraoperative blood loss, incidence of postoperative complications, and the effect of intraoperative use of the device were analyzed. All 10 beagles were successfully operated; the mean operation time was 19.7 ± 3.53 min (range 15–26 min), and the postoperative blood loss was < 10 mL. No surgical complications occurred. During the operation, the internal grasper was firmly clamped, the auxiliary operation field was well exposed, and the interference of the main operation hole instruments was effectively reduced. We provide preliminary experimental evidence of the safety and feasibility of magnetic anchor technique-assisted thoracoscopic lobectomy.

Lung cancer is the most common type of cancer in the world, and the main cause of cancer-related deaths. In 2020, an estimated 1.8 million people died of lung cancer across the world1. Thoracoscopic lobectomy is the most commonly used surgical method for the treatment of lung cancer. The traditional thoracoscopic operation requires three ports, which significantly reduces surgical trauma compared with thoracotomy. However, owing to the advances in the field of minimally-invasive surgery, fewer and smaller ports may further reduce postoperative pain2. In recent years, the concept of single operation hole and single-hole operation have been introduced in thoracoscopic surgery and applied in clinic3. However, after reducing the number of ports, all operating instruments need to enter and exit the thoracic cavity through the same operating hole, leading to collision and interference between instruments, forming a chopstick effect and increasing the difficulty of operation.

Magnetic anchor technique (MAT) entails the use of magnetic attraction between magnets and magnets, or magnets and paramagnetic substances, to make the anchoring magnets non-contact spatial anchoring of the target magnets4. MAT is currently widely used in laparoscopic surgery. It can facilitate cholecystectomy and appendectomy, but it has rarely been used in thoracoscopic surgery. Based on the MAT, our team designed a magnetic anchoring internal grasper suitable for thoracoscopic surgery to assist in the ports-reducing thoracoscopic surgery, and further verified its safety and feasibility in animal experiments.

The experiment was approved by the animal experiment ethics committee of the Xi'an Jiaotong University (ethics approval number: XJTULAC2019-1003). The research protocol and all experimental procedures were strictly in accordance with the Guidelines for the Care and Use of Experimental Animals issued by the Xi’an Jiaotong University Medical Center.

Ten male Beagles (age: 1–6 years; weight: 8–12 kg) were used as the experimental group. This is an exploratory study, so there is no control group. The animals were obtained from the Experimental Animal Center, College of Medicine, Xi’an Jiaotong University (Xi’an, China) and acclimatized to laboratory conditions (23 °C, 12 h/12 h light/dark, 50% humidity, ad libitum access to food and water) for one week prior to commencing the experiments. All animal experiments are carried out in accordance with the Declaration of the Helsinki Convention on the Use and Care of Animals. Piperazine hydrochloride was injected intramuscularly every 12 h to relieve pain for two days after surgery, and 0.5 g cefazolin sodium was injected intramuscularly every 12 h to prevent infection for three days after surgery. At the end of the study, all animals were euthanized with excess barbital sodium (intravenous, 150 mg/kg pentobarbital sodium) and tissues were collected.

The magnetic anchoring device consists of an anchoring magnet and an internal grasper. The anchor magnet is a cylindrical magnet with a height of 140 mm and a diameter of 50 mm. The internal grasper is formed by connecting the target magnet and the tissue grasping forceps through a wire. The target magnet is a cylindrical magnet with a height of 15 mm and a diameter of 10 mm. The tissue grasping forceps is made of non-paramagnetic material. All magnets are made of N45 sintered neodymium iron boron material, and the surface is protected by nickel plating (Fig. 1).

Magnetic anchoring device. (A) The internal grasper. (B) The anchoring magnet.

There is enough attractive force between the target magnet and the anchor magnet to play a traction effect. In line with the actual environment of thoracoscopy, we designed a cylindrical target magnet with a height of 15 mm and a diameter of 10 mm. We measured the change of its magnetic force with change in the distance between the two magnets (Fig. 2). We found that its traction can reach 44 N, and the existing dimensions can provide sufficient traction. In operation, the traction force can be flexibly adjusted by changing the position of the anchoring magnet according to the needs of tissue traction. The force of 2-8 N is sufficient for lobar traction in the Beagle.

Measurement of magnetic force–displacement curve. (A) Schematic illustration of magnetic force–displacement curve measurement. (B) Magnetic force–displacement curve.

Before the operation, Beagles were fasted for 12 h and denied access to liquids for 6 h. Beagle dogs were anesthetized by intravenous injection of 3% pentobarbital sodium injection (1 mL/kg), and their left sides were fixed in a supine position. Intramuscular injection of cefazolin sodium 0.5 g was administered 30 min before surgery to prevent infection. After intubation of Beagle dogs with double-lumen endotracheal tube, the right lung was sealed and the left lung was ventilated. A small incision of approximately 1 cm in length was made in the 7th intercostal space in the right mid-axillary line, a trocar was inserted, and a thoracoscope was placed; a small incision of approximately 2 cm in length was made in the fourth intercostal space in the anterior axillary line as the main operation hole. We assumed a lesion and performed surgical resection. The internal grasper was inserted into the thoracic cavity from the main operation hole using titanium alloy forceps, and clamped around the target lung tissue. The position of the anchoring magnet was moved outside the body, and the target magnet was controlled by the magnetic field to pull the lung tissue and expose the surgical field (Fig. 3). The target magnet was used to pull the lung lobes to assist in the cauterization of lung ligaments and adhesion tissues. Subsequently, we changed the clamping position of the internal grasper to expose the interpulmonary fissures, and tried to dissect the hilum. We can also change the direction and strength of tissue traction by moving the anchor magnet throughout the procedure. After the blood vessels and trachea were separated and cleared, the internal grasper was clamped near the hypothetical lesion, and the position of the target magnet was changed to lift the lung lobe. Then a linear cutting stapler was used to excise the hypothetical lesion. After cutting the hypothetical lung lesion, we used the endoscopic instrument to attach to the tail of the internal grasper, and extracted it along with the target lung tissue through the main operation hole. The thoracic cavity was injected with water to expand the lungs, and no air leakage was observed at the cutting edge, and a thoracic drainage tube was inserted. We reserved sutures in a small incision in the mid-axillary line, and inserted a drainage tube to a suitable position in the chest cavity. The main operating hole was closed by stitching layer by layer. Subsequently, the anesthesiologist was asked to continue to expand the lungs. The drainage tube was placed under the surface of 500 mL bottled saline to expel the gas in the pleural cavity, and then the drainage tube was quickly pulled out and the incision was closed.

Schematic illustration of the use of a magnetic anchoring device in assisting thoracoscopic surgery. (A) Assist in exposing the hilum and separating the associated blood vessels. (B) Assist in the separation of ligaments. (C) Assist in the resection of lung tissue. (D) Take out the internal grasping forceps and lung tissue through the endoscopic device.

Intramuscular injection of pethidine hydrochloride was administered every 12 h for analgesia for two days after surgery, and intramuscular injection of cefazolin sodium 0.5 g was administered every 12 h for 3 days after surgery to prevent infection. We fed beagles regularly and monitored their condition. After 2 weeks of monitoring, all beagles were euthanized.

Data pertaining to blood loss, operation time, postoperative complications, and other surgical parameters were collected. The intraoperative problems were also recorded. Descriptive analysis of the collected data was performed with SPSS 22.0 software. Normally distributed continuous variables were expressed as mean ± standard deviation while the categorical variables were expressed as frequency and percentage (%).

All beagles successfully underwent thoracoscopic lobectomy assisted by the magnetic anchoring device. The average operation time was 19.7 ± 3.53 min (range 15–26 min). The intraoperative blood loss was < 10 mL. All beagle dogs showed good postoperative healing. There were no obvious complications such as pleural effusion, pneumothorax, severe wound infection, or blood in the lungs.

The magnetic anchor grasping forceps can clamp the lung lobes securely during the operation, without slippage, and successfully assisted the thoracoscopic surgery (Fig. 4). At the same time, the grasping forceps did not cause any tearing damage to the lung tissue. The external anchoring magnet can exert adequate traction force to pull the internal grasper for surgical operation. The use of a magnetic anchoring device can well assist the exposure of the surgical field. With its help, we successfully performed the resection of the hypothetical lesion. The magnetic anchoring device replaced the traditional endoscopic grasping forceps, effectively alleviating the collision and interference of equipment during the single-hole operation.

Intraoperative photographs showing the use of magnetic anchoring device to assist thoracoscopic surgery. (A) Use of titanium alloy forceps to insert the internal grasper into the body. (B) The internal grasper is clamped in a suitable position. (C) The position of the external anchoring magnet was moved to change the position of the internal grasper. (D) Assist in the exposure of lung fissures. (E, F) Assist in resection of lung tissue. (G, H) The internal grasper and target lung tissue is taken out. (I) The removed internal grasper and target lung tissue. (“*” shows the internal grasper, “ + ” shows the anchoring magnet.).

After thoracoscopic lobectomy was first proposed by Lewis in 19925, the field of thoracoscopic surgery has shown rapid advances and has gradually replaced thoracotomy. Subsequently, thoracic surgeons pursued more minimally-invasive methods, and proposed single-port and double-port surgery. In 2004, Rocco G completed the first single-port thoracoscopic wedge resection6. Subsequently, efforts were made to further develop thoracoscopic surgery with reduced ports. Several studies have shown that reducing the number of ports reduces intraoperative bleeding, postoperative pain, drainage time, and hospital stay3,7,8. However, irrespective of the method, more operating instruments will inevitably need to pass in and out of the thoracic cavity through the same port, which is likely to cause instrument collision and interference with surgical operations9,10. In addition, it also increases the difficulty of learning for the surgeon11.

The magnetic anchor technique-assisted laparoscopic surgery was first reported by the Cadeddu team. They developed a magnetic anchoring and guidance system (MAGS) and proposed the replacement of some traditional laparoscopic instruments with this system12. They used this system to successfully perform transvaginal cholecystectomy13 and laparoscopic nephrectomy14 in several pigs. Clinical trials of this system were subsequently carried out15. The results demonstrated the safety and feasibility of magnetic anchor technique-assisted ports-reducing laparoscopic surgery, which can reduce instrument collisions and improve the operating space.

Kume et al. developed a magnet-retracting forceps16 and used it to pull out the gallbladder during laparoscopic cholecystectomy in a pig model. The device afforded good exposure of the surgical field. Subsequently, Dominguez et al. developed the TD-magnet system and used the device to perform cholecystectomy in 40 patients17. They solved the shortcomings of the device designed by Kume et al., separated the magnet and the gallbladder, and demonstrated a better range of motion. At the same time, Dominguez wrapped the magnets to allow simultaneous use of multiple magnets in the body.

Under the leadership of Professor Lv Yi, our team has summarized the application of magnetic force and further explored and conducted research in recent years. We proposed a magnetic surgical system, which incorporates a variety of technical theories. It mainly includes magnetic anchor technique (MAT), magnetic compression technique (MCT), magnetic navigation technique (MNT), magnetic levitation technique (MLT), magnetic tracer technique (MTT), and magnetic drive technique (MDT)4. Using the theory of magnetic anchor technology, we designed a magnetic anchoring internal grasper, which has been successfully applied to laparoscopic cholecystectomy18, laparoscopic hysterectomy19, and laparoscopic appendectomy.

At present, the use of magnetic anchor technology in thoracic surgery mainly includes the 3MP system for treatment of pectus excavatum20 and to assist thoracoscopic surgery. To the best of our knowledge, there are few reports on the use of magnetic anchor technology for thoracoscopic surgery. Martinez-Ferro et al. completed thoracoscopic lung wedge resection in a patient applying the magnetic anchoring device to single port thoracoscopic surgery in 201121; however, they did not conduct further studies. We have accumulated experience in the application of magnetic anchored internal grasping forceps to assist laparoscopic puncture-reduction surgery in the early stage. Magnetic anchor technique is mostly used in laparoscopic surgery, but in fact, the bony structure of the chest wall provides more stable physical support and wider traction space than the abdominal wall. Therefore, we believe that magnetic anchor technique will have a better performance in thoracoscopic lobectomy. In this study, the magnetically anchored built-in grasping forceps were extended to assist thoracoscopic ports-reduction surgery, and we assessed the feasibility and safety of its use in beagle dogs. In assisted thoracoscopic puncture-reduction surgery, the magnetic anchored built-in grasping forceps provided good exposure of the surgical field. It allowed for good exposure and dissection of the blood vessels and bronchus. Moreover, the grasping forceps provided enough traction force to assist in cutting the lung tissue.

Compared with the TD-magnet system, the grasping forceps designed by us has a good range of motion and reduces the use of wires to control its activities. We use a silk thread to connect the internal grasper and the target magnet, so that the target magnet and the tissue grasper do not have to form a fixed angle, which increases the range of movement of the target magnet. The position of the anchoring magnet is adjusted to control the internal grasping forceps to expose the surgical field. At the same time, the distance between the anchoring magnet and the chest wall is adjusted to adjust the traction force. On the side of the target magnet, we adopt the magnetic shielding technology to effectively prevent the attraction between the target magnet and the cavity mirror device. At the same time, only the tail end of the target magnet is exposed, which is helpful in withdrawal of the target magnet. Although we have documented the variation in the magnetic force of the two magnets with change in the distance, it still requires the surgeon to learn by practice and gain experience in controlling the traction force during the operation; however, this does not entail a steep learning curve. The disadvantage is that it may necessitate an assistant to control the anchoring magnet, but if an effective external holding device is used, the need for assistance can be avoided. Sintered neodymium iron boron material is a commonly used material in magnetic anchor device at present21,22,23. The surface protection method can be nickel coating, titanium nitride coating and so on. This has been reported by other authors and in our previous articles. The material is safe for humans.

In this study, we only used a single target magnet to assist surgery. The MAGS developed by the Cadeddu team can replace multiple laparoscopic devices and accommodate multiple magnetic anchoring devices in the abdominal cavity. However, further studies are required to assess the feasibility of replacing the endoscopic grasping forceps with more magnetic anchoring devices in the thoracic cavity. We believe that magnetic anchoring devices should not be used too much. On the one hand, the capacity of the thoracic cavity is fixed, and its ability to accommodate multiple magnetic anchoring devices, like the abdominal cavity, needs to be further discussed. On the other hand, a magnetic anchor internal grasper is sufficient for thoracoscopic wedge resection, and the built-in target magnet may be interfered by multiple external anchoring magnets, thereby affecting the operation.

Although we have achieved experimental success, this research still has shortcomings. First of all, in our study, we mainly performed the resection of the right lung tissue, and did not make repeated attempts on multiple lung lobes. Further studies are required to assess the suitability of this device for other more complex disease models. Secondly, we did not make a statistical comparison of the effect of using or not using a magnetic anchoring device on the operation, but just made a judgment based on the surgeon’s experience. In addition, because there are still differences in the structure of beagles and humans, whether the device has the same effect in the human body needs further research. However, we believe that magnetic anchor technology can play a useful role in lung resection, lobectomy, and other operations. We can thoroughly extend this technology to single-port thoracoscopic surgery to achieve a more minimally invasive effect.

The magnetic anchor grasping forceps designed based on magnetic anchor technique can assist in thoracoscopic surgery, effectively reduce the collision between instruments, and facilitate good surgical field exposure. We believe that the magnetic anchor technique has potential application value in thoracoscopic surgery and is worthy of further research.

The datasets used and analyzed during the current study available from the corresponding author on reasonable request.

Sung, H. et al. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J. Clin. 71, 209–249 (2021).

Article Google Scholar

Coletta, D., Mascioli, F., Balla, A., Guerra, F. & Ossola, P. Minilaparoscopic cholecystectomy versus conventional laparoscopic cholecystectomy. J. Laparoendosc. Adv. Surg. Tech. A. 31, 648–656 (2021).

Article Google Scholar

Gonzalez-Rivas, D. et al. Uniportal video-assisted thoracoscopic lobectomy: Two years of experience. Ann. Thorac. Surg. 95, 426–432 (2013).

Article Google Scholar

Yan, X. P. et al. Exploration and establishment of magnetic surgery. Chin. Sci. Bull.-Chin. 64, 815–826 (2019).

Article Google Scholar

Lewis, R. J., Caccavale, R. J., Sisler, G. E. & Mackenzie, J. W. One hundred consecutive patients undergoing video-assisted thoracic operations. Ann. Thorac. Surg. 54, 421–426 (1992).

Article CAS Google Scholar

Rocco, G., Martin-Ucar, A. & Passera, E. Uniportal VATS wedge pulmonary resections. Ann. Thorac. Surg. 77, 726–728 (2004).

Article Google Scholar

Tu, C. C. & Hsu, P. K. Global development and current evidence of uniportal thoracoscopic surgery. J. Thorac. Dis. 8, S308-318 (2016).

PubMed PubMed Central Google Scholar

Abouarab, A. A., Rahouma, M., Kamel, M., Ghaly, G. & Mohamed, A. Single versus multi-incisional video-assisted thoracic surgery: A systematic review and meta-analysis. J. Laparoendosc. Adv. Surg. Tech. A. 28, 174–185 (2018).

Article Google Scholar

Wang, L., Liu, D., Lu, J., Zhang, S. & Yang, X. The feasibility and advantage of uniportal video-assisted thoracoscopic surgery (VATS) in pulmonary lobectomy. BMC Cancer 17, 75 (2017).

Article Google Scholar

Gonzalez-Rivas, D., Yang, Y. & Ng, C. Advances in uniportal video-assisted thoracoscopic surgery: pushing the envelope. Thorac. Surg. Clin. 26, 187–201 (2016).

Article Google Scholar

Drevet, G. & Ugalde Figueroa, P. Uniportal video-assisted thoracoscopic surgery: safety, efficacy and learning curve during the first 250 cases in Quebec, Canada. Ann. Cardiothorac. Surg. 5, 100–106 (2016).

Article Google Scholar

Park, S. et al. Trocar-less instrumentation for laparoscopy: magnetic positioning of intra-abdominal camera and retractor. Ann. Surg. 245, 379–384 (2007).

Article Google Scholar

Scott, D. J. et al. Completely transvaginal NOTES cholecystectomy using magnetically anchored instruments. Surg. Endosc. 21, 2308–2316 (2007).

Article Google Scholar

Zeltser, I. S. et al. Single trocar laparoscopic nephrectomy using magnetic anchoring and guidance system in the porcine model. J. Urol. 178, 288–291 (2007).

Article Google Scholar

Cadeddu, J. et al. Novel magnetically guided intra-abdominal camera to facilitate laparoendoscopic single-site surgery: initial human experience. Surg. Endosc. 23, 1894–1899 (2009).

Article Google Scholar

Kume, M. et al. A newly designed magnet-retracting forceps for laparoscopic cholecystectomy in a swine model. Minim. Invasive Ther. Allied Technol. 17, 251–254 (2008).

Article Google Scholar

Dominguez, G. et al. Retraction and triangulation with neodymium magnetic forceps for single-port laparoscopic cholecystectomy. Surg. Endosc. 23, 1660–1666 (2009).

Article Google Scholar

Bai, J. G. et al. Clinical application of magnetic anchor technique in laparoscopic cholecystectomy. J. Laparosc. Surg. 24, 782–785 (2019).

Google Scholar

Kang, S. R. et al. Experimental study on magnetic anchor device in assisting trocar-less laparoscopic hysterectomy. China Med. Devices. 35, 56–58 (2020).

Google Scholar

Graves, C. E. et al. Magnetic mini-mover procedure for pectus excavatum IV: FDA sponsored multicenter trial. J. Pediatr. Surg. 52, 913–919 (2017).

Article Google Scholar

Padilla, B. E., Dominguez, G., Millan, C. & Martinez-Ferro, M. The use of magnets with single-site umbilical laparoscopic surgery. Semin. Pediatr. Surg. 20, 224–231 (2011).

Article Google Scholar

Shang, Y. et al. An application research on a novel internal grasper platform and magnetic anchoring guide system (MAGS) in laparoscopic surgery. Surg. Endosc. 31, 274–280 (2017).

Article Google Scholar

Zhang, L. et al. Internal grasper and magnetic anchoring guidance system in gynecologic laparoendoscopic single-site surgery: a case series. J. Minim. Invasive Gynecol. 28, 1066–1071 (2021).

Article Google Scholar

Download references

This work was supported by the Key Research & Development Program-Social Development of Shaanxi Province of China (2021SF-163) and the Innovation Capability Support Plan of Shaanxi Province of China (2020KJXX-022).

These authors contributed equally: Yixing Li and Miaomiao Zhang.

Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, No. 277 West Yanta Road, Xi’an, Shaanxi, 710061, People’s Republic of China

Yixing Li, Miaomiao Zhang, Yi Lyu & Xiaopeng Yan

Department of Thoracic Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, Shaanxi, People’s Republic of China

Yixing Li & Yong Zhang

National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, Shaanxi, People’s Republic of China

Miaomiao Zhang, Aihua Shi, Yi Lyu & Xiaopeng Yan

Qide College, Xi’an Jiaotong University, Xi’an, Shaanxi, People’s Republic of China

Peinan Liu & Hanzhi Zhang

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

Conception and design, Y.L. and X.Y.; Administrative support, Y.L. and X.Y.; Provision of study materials, Y.X.L., M.Z., A.S., P.L., H.Z., Y.Z. and X.Y.; Collection and assembly of data, Y.X.L., M.Z., A.S., P.L. and H.Z.; Data analysis and interpretation, Y.X.L., M.Z., A.S., P.L., H.Z. and X.Y.; Manuscript writing, Y.X.L. and M.Z.; Final approval of manuscript, All authors.

Correspondence to Yi Lyu or Xiaopeng Yan.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

Li, Y., Zhang, M., Shi, A. et al. Magnetic anchor technique-assisted thoracoscopic lobectomy in beagles. Sci Rep 12, 11916 (2022). https://doi.org/10.1038/s41598-022-16050-4

Download citation

Received: 30 April 2022

Accepted: 04 July 2022

Published: 13 July 2022

DOI: https://doi.org/10.1038/s41598-022-16050-4

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

Scientific Reports (2023)

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.